Huawei H19-371_V1.0-ENU exam is a certification exam for individuals who want to acquire the Huawei Certified Pre-sales Associate - Digital Power certification. H19-371_V1.0-ENU exam measures the candidate's knowledge and skills in the area of digital power products and solutions. H19-371_V1.0-ENU exam is designed to validate the candidate's understanding of digital power products and solutions, including their features, benefits, and applications.

 

NEW QUESTION # 260
What type of equipment room is physically isolated in the power distribution room (multiple choice)?

  • A. Class C
  • B. Class B
  • C. Class A
  • D. Tier IV

Answer: C,D


NEW QUESTION # 261
The NetEco V6R8 version of the data center management system can support the access of up to 100,000 measuring points on a single server.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 262
The name of the controller that controls the sunroof in Fusionmodule2000 is ( )

  • A. Sunroof Actuator
  • B. AC actuator
  • C. Access Control Actuator

Answer: A


NEW QUESTION # 263
The environmental parameters of the data center host room are: ( ).

  • A. The relative humidity is not more than 60%.
  • B. Dew point temperature 5.5~ 15C .
  • C. No condensation in the computer room
  • D. Satisfy both ABCD.
  • E. Temperature 18~27C

Answer: D


NEW QUESTION # 264
The NetEco management system realizes the video surveillance function of the equipment room by integrating the Huawei eSpace VCN video solution.

  • A. False
  • B. True

Answer: B


NEW QUESTION # 265
What are the fire-fighting linkage functions of FusionModule2000?

  • A. Channel light on
  • B. Channel gate magnetic power down
  • C. Air conditioner off
  • D. Sunroof Flip

Answer: A,B,C,D


NEW QUESTION # 266
Which of the following is true about the micro-module and fire protection system? ( )

  • A. ECC800 can control sunroof rollover
  • B. The building fire protection system can send fire signal to the computer room controller (ECC800)
  • C. When a fire alarm occurs in the channel, the computer room controller (ECC800) can send the signal to the building fire protection system
  • D. ECC800 controller can be linked with building fire

Answer: A,B,C,D


NEW QUESTION # 267
NetCol5000-A042H Full-cabinet row-level air-cooled variable frequency precision air conditioner can match the outdoor unit model and adaptable temperature range: ( )

  • A. NetCol500-A026 (-20~45)
  • B. NetCol500-A088 (-5~55)
  • C. NetCol500-A072 (-5~55)
  • D. NetCol500-A036 (-40~45 need to bring low temperature components)

Answer: D


NEW QUESTION # 268
Which of the following statements are true about the iBattery battery management system? ( )

  • A. iBattery can be connected to UPS
  • B. iBOX can be powered by DC 48V or POE
  • C. iBattery can manage battery
  • D. The iBat signal is wirelessly connected to the iBOX

Answer: A,B,C,D


NEW QUESTION # 269
According to the ICT Research 2018 statistical report, the market share of Huawei's line-level temperature control products in China in 2017 is: ( )

  • A. Fourth
  • B. Second
  • C. First
  • D. third

Answer: C


NEW QUESTION # 270
The single cooling capacity range of the water-cooled centrifugal unit is:

  • A. 200-2000kW
  • B. 100-1000kW
  • C. 500-5000kW
  • D. 300-3000kW

Answer: D


NEW QUESTION # 271
UPS5000-A can significantly reduce the harmonic pollution to the power grid. In the case of linear full load, the input current waveform distortion THDi is

  • A. 0.02
  • B. 0.03
  • C. 0.01
  • D. 0.05

Answer: B


NEW QUESTION # 272
FusionModule500&FusionModule800 can be equipped with emergency fans

  • A. True
  • B. False

Answer: B


NEW QUESTION # 273
Huawei Neteco network management supports mobile APP management

  • A. False
  • B. True

Answer: B


NEW QUESTION # 274
When the operating temperature of the UPS2000-A is too high ( ).

  • A. Switch battery mode
  • B. Switch to bypass mode
  • C. Stop output, load power off
  • D. no action

Answer: B


NEW QUESTION # 275
Which are standard configurations in the typical configuration of FusionModule800? (

  • A. Smoke sensor, door sensor, pad, water immersion, simple wiring trough, video
  • B. Smoke sensor, temperature and humidity, pad, SMS alarm, mobile APP, automatic pop-up door
  • C. Temperature and humidity, door sensor, pad, water flood, video, mobile APP

Answer: B


NEW QUESTION # 276
Fusionlodule500 uses natural heat dissipation (

  • A. False
  • B. True

Answer: B


NEW QUESTION # 277
The communication between the NetEco management system and the ECC800 collector adopts Huawei's proprietary protocol BIN protocol. ( ).

  • A. False
  • B. True

Answer: B


NEW QUESTION # 278
......